Negotiable
The date of payment from buyers deliver within days
Guangdong
Long-term effective
2018-04-03 23:55
313
Company Profile
Anyhertz Drive (Shenzhen) Co.,LtdBy certification [File Integrity]
Contact:fosite(Mr.)
Email:
Telephone:
Phone:
Area:Guangdong
Address:Guangdong
Heavy load application frequency inverter
We are professional manufacturer of Heavy load frequency inverter.We have products from 380V three phase from 1.5kw to 630kw. It can be used to control AC motor speed and save enegy for lift ,tower crane for example.Our product has exported to 45 countries and has CE certificates.
1. Heavy load frequency inverter.
LCD keypad,English, Russian, French, German,Spanish and Chinese language available. Four control model for option:VF Control, V/F control with PG, Vector control, Vector control with PG,inbuilt PID function
2. Basic Parameters of Heavy load application frequency inverter.
3.Main features and application of the Heavy load application frequency inverter.
4. Main parameters of Heavy load application frequency inverter.
Item |
Specification |
/frequency |
Three phase 380~440V 50Hz/60Hz |
Allowed fluctuation |
Voltage: +10% ~ -15%; Frequency: ±5% |
Three phase 0~380V |
|
0~400.00Hz |
|
Overload capacity |
150% of rated current – 1Min |
Control mode |
V/F control, V/F control with PG, Vector control, Vector control with PG |
LCD display |
Six languages for option: Chinese, English, Russian, German, French, Spanish |
Starting torque |
180% 1Hz (200%,0Hz in the mode of vector control with PG) |
Speed control range |
1:100 (1:1000 in the mode of vector control with PG ) |
Speed control accuracy |
±0.2% (±0.02% in the mode of vector control with PG ) |
Speed response |
5Hz ( 30Hz in the mode of vector control with PG ) |
Torque control accuracy |
±5% |
Torque response |
20Hz ( 40Hz in the mode of vector control with PG ) |
Frequency control range |
0.1~400Hz |
Frequency accuracy |
Digital command: ±0.01% (-10℃~ +40℃); Analog command: ±0.1% (10℃~ 25℃); |
Frequency reference resolution |
Digital command: 0.01Hz; Analog command: 0.03Hz / 60Hz |
Frequency reference signal |
-10V~+10V; 0~+10V (20KΩ); 4~20mA |
Output freq. resolution |
0.01Hz |
Communication |
RS485 interface: 485+, 485- (MODBUS Protocol) |
Acc/Dec time |
0.01 ~ 6000s |
Braking torque |
20% (up to 150% for models with inbuilt braking function and external braking resistor) |
Voltage/Frequency characteristics |
15 kinds of Voltage/Frequency characteristics for option; And user can set V/F characteristics all by themselves. |
Protection function |
Overvoltage, undervoltage, overload, overheat, stall, grounding fault, charging protection. etc |
Ambient temperature |
-10℃ ~ +40℃. Deration above 40℃ |
Humidity |
20~90%RH, non-condensing |
Protection rating |
IP20 |
Cooling mode |
Forced air cooling |
5. Details of heavy load frequency inverter
6.Corner of Factory
8. Heavy load frequency inverter advantage:
Adopting advanced vector control functions, it has the characteristics of high voltage utilization, high power factor, fast dynamic response, high precision, low noise, low torque and high torque output. At the same time, it has the advantages of good dynamic performance and rich application functions, which can meet the higher demands of customers.
9. All heavy frequency inverter have to go through 4 checks in the whole process:
10. Heavy load frequency inverter Wirings diagram:
http://www.anyhzdrive.com/